Image Name

Product Center

Product Center

Image Name

VLC series

VLC series
+
  • VLC series

VLC series


Voltage Rating:

600V/1000V

Current Rating:

950A MAX

Size:

--

Operating Class:

--

Safety Certification:

CE/UL/CUL*

Environmental Certification:

RoHS/REACH/PF

Compatible specifications:

LCH;PDBs;MPDB

Remarks:

*For specific certification information, please contact us.

I want to inquire
  • 产品描述

    Specifications
    Voltage Rating :600V/1000V
    Current Rating :Based on NEC Table 310.16, using 75°C copper wire
    Material :Phenolic rated at 150°C and Thermoplastic rated at 125°C
    Connector:Standard: Highly conductive aluminum, tin plated
                        Copper: Highly conductive copper, tin plated
    Flammability Rating:UL94 V-0
    Environmental:RoHS compliant


    Ordering Information
    Power distribution blocks offer a safe, convenient way of splicing cables, providing a fixed junction tap-off point or spltting primary power into secondary circuits.
    VLx2xxx-DIN series offers integral DIN-Rail mount and an optional hinged safety cover.
    Optional power distribution block covers provide protection against accidental shorting between poles caused by
    loose wires, tools, or other conductive material. They also protect personnel from accidentally contacting energized connectors. To order protective covers, match the number of poles for the block to the cover.


    Applications
    Typical applications include heating, air conditioning and refrigeration systems, elevator systems, material handling equipment, control panels, motor controls, switchgear, and anywhere power needs to be distributed to more than one load.


    Connectors
    Box lug connectors are designed for use with a single, solid or class B or C stranded conductor. Use of more than one conductor per connector opening or use of extra-flexible, fine-stranded conductors, such as welding cable, voids the UL Listing and may cause overheating. Manufacturers of cable terminations can furnish crimp-on sleeves for fine stranded conductors which permit these conductors to be used with box lugs.


    Ampere Ratings
    The ampere rating per pole for power distribution blocks is based on the line ampacity of 75°C insulated conductors per NEC@ Table 310.16. If 60°C insulated conductors are used,load must not exceed the ampacity of 60°C conductors.Use of conductors rated in excess of 75°C is permitted (for example 90°C), however, load must not exceed the ampacity of 75°C conductors.

     

     